RFTEMP101 - Thermocouple Based Temperature Transmitter
Additional features include programmable transmission interval, programmable calibration, automatic cold junction compensation and linearization and real time monitoring. Its real time clock enables all data to be time and date stamped. The device will directly accept any of the 8 most common thermocouple types. In addition, the ambient temperature is also transmitted and provided to the user as a second temperature channel. Its reading rate (transmission rate) is user selectable and can range from 1 per 5 seconds to 1 per day. Once activated, this device will continually transmit readings. Its small size allows it to fit almost anywhere. The RFTemp is easy to install. Data retrieval is simple. Plug it the receiver into an empty com port and our easy to use software does the rest. The RFTemp requires minimal effort to configure. The software used to configure the RFTemp requires no programming skills and enables users to effortlessly select reading rate, user id and initiate the start of data collection within moments after users connect their hardware. A simple plug-in connection is all that is required to connect our RF Receiver to your PC. Up to 8 RFTemp’s can be used to transmit data to 1 receiver.
|
RFTemp101 Logger Specifications:
Transmission Distance: 300 feet.
Transmitters Per Receiver: 8
Internal Channel
Temperature Accuracy: 0.5 deg C.
Temperature Resolution: 0.5 deg C.
Temperature Range: -40 Deg C to + 75 Deg C.
Remote Channel
| Thermocouple Type | Range | Resolution | Accuracy |
| J | -200 to + 1190 deg. C | 0.1 deg. C | 1 deg. C |
| K | -260 to + 1370 deg. C | 0.1 deg. C | 1 deg. C |
| T | -260 to + 390 deg. C | 0.1 deg. C | 1 deg. C |
| E | -260 to + 990 deg. C | 0.1 deg. C | 1 deg. C |
| R | -40 to + 1760 deg. C | 0.1 deg. C | 1 deg. C |
| S | -40 to + 1760 deg. C | 0.1 deg. C | 1 deg. C |
| B | 50 to + 1810 deg. C | 0.1 deg. C | 1 deg. C |
| N | -260 to +1290 deg. C | 0.1 deg. C | 1 deg. C |
|
Thermocouple connection: |
Screw Terminal |
|
Thermocouple Types: |
J, K, T, E, R, S, B, N |
|
Thermocouples: |
Factory supplied to customer specifications. |
|
Input Channels: |
2 - 1 internal and 1 external |
|
Input Impedance: |
>1Meg and 30pF |
|
Temperature Calibration: |
Digital Calibration available through software. Calibration correction value stored in device for internal channel as well as thermocouple. |
|
Cold Junction Compensation: |
Automatic |
|
N.I.S.T. Traceable: |
N.I.S.T. certificates available. |
|
Calibration Date: |
Automatically recorded in non-volatile memory within device. Reminds user when calibration is required. |
|
Transmission Interval: |
2 seconds, 5 seconds, 10 seconds, 15 seconds, 30 seconds, 1 minute, 5 minutes, 10 minutes, 15 minutes, 30 minutes, 1 hour, 2 hours, 4 hours, 8 hours, 24 hours. |
|
Start Time: |
The start time and date is completely programmable enabling users to synchronize multiple devices and delay start of data collection until device is in place. |
|
Real Time Recording: |
Device may be used to with pc to monitor and record data in real time. |
|
Red Visual Indicator: |
Red LED flashes at the reading interval to indicate device operational. |
|
User-Replaceable Battery: |
1 year typical. |
|
Time Accuracy: |
± 1 minute per month at 20 Deg C. |
|
Data Format: |
Date and Time stamped Deg C, Deg F, Deg K, Deg R. |
|
Shock resistance: |
Drop proof to 5’ |
|
Weight: |
1 oz (25.5g) |
|
Computer Interface: |
PC serial or RS232C COM |
|
Software: |
Windows 95-based software for complete control and operation. |
|
Operating Environment: |
-40 Deg C to 75 Deg C, 0 to 95% RH. (non-condensing) |
|
Dimensions: |
0.6" x 1.4" x 2.15" (15mm x 35mm x 54mm) |
|
Material: |
ABS Plastic |
We have a full line of catalogs that we can send at your request. Please
feel free to
Phone: 501 589-2947...........Fax: 501 589-2285.........Email:
gfgw@hotmail.com
![]()